Ruggedized Rack Enclosure Edge Solution

DDC-CabTech > Ruggedized Rack Enclosure Edge Solution

Ruggedized R-Series

The R-Series line of enclosures enables the rapid deployment of IT infrastructure into any environment imaginable, while providing secure, clean-room quality data center conditions, which can support any rack mountable hardware.

Ruggedized DDC R-Series Cabinet Enclosures
Micro data center for edge computing
Edge-Deployments
Edge Deployments

When environmental conditions are not conducive for IT equipment, R-Series enclosures deliver turnkey data center capabilities, on-demand!

mobile data center
Mobile Data Centers

Providing rack space, cooling, fire suppression, security, monitoring, and management all in a succinct, modular package.

Micro data center for edge
Variety of Configurations

On location, on a temporary basis, or if the requirement is for permanent infrastructure where data center resources do not exist.

ruggedized rack enclosures and cabinets
Removes Obstacles

Supporting any rack mountable hardware, rapidly deploy anywhere the demand exists.

Our Services

 

how can we help you?

We pride ourselves on a great customer service experience for all.

Ruggedized R-Series

When mobility is key, the R-Series line of enclosures delivers data center capabilities anywhere the demand exists. With integrated DX cooling, fire suppression, and security, combined within a 100% self-contained and mobile package, IT infrastructure can be deployed in minutes, in any environmental condition imaginable.

Select the correct RU (rack unit) size for your needs, choose rolling casters or pallet jack mounting for easy-mobility, and you have your own data center on wheels, all you supply is power!

mobile data center for IoT
  • Density Capability
    293W-1.75kW
  • Rack Units
    12U
  • Measurements (HxWxD)
    32.5 X 25.5 X 55 (in)
    82.5 x 65 x 140 (cm)
  • Max Equipment Depth
    32 (in) 81.3 (in)
  • Unit Weight
    310 (lbs) 141 (kg)
  • Controls
    Automated Cooling/HVAC Control
  • Fire Suppression/Risk Management
    Integrated, Inert Gas Based
  • Cabinet Power Distribution
    Optional
  • Power Management
    Optional based on location
  • Cooling System
    Dx Air Conditioning
  • Water Temp Operating Range
    NA
  • Flow Rate
    NA
  • Air Flow
    175-350 CFM
    (297-594 m3/h)
  • Inter-Cabinet Cable Mgmt.
    Optional
  • Security Options
    Locks/Biometrics/2FA
edge data center solution
  • Density Capability
    2.3-3.5kW
  • Rack Units
    24U
  • Measurements (HxWxD)
    58 x 28.5 x 58 (in)
    173 x 71 x 173 (cm)
  • Max Equipment Depth
    29 (in) 73.66 (cm)
  • Unit Weight
    675 (lbs) 306 (kg)
  • Controls
    Automated Cooling/HVAC Control
  • Fire Suppression/Risk Management
    Integrated, Inert Gas Based
  • Cabinet Power Distribution
    Optional
  • Power Management
    Optional based on location
  • Cooling System
    Dx Air Conditioning
  • Water Temp Operating Range
    NA
  • Flow Rate
    NA
  • Air Flow
    350-800 CFM
    (594-1,360 m3/h)
  • Inter-Cabinet Cable Mgmt.
    Optional
  • Security Options
    Locks/Biometrics/2FA
mobile data center for high density workloads
  • Density Capability
    2.3kW-7.9kW
  • Rack Units
    30U
  • Measurements (HxWxD)
    68.5 x 28.5 x 58 (in)
    181 x 71 x 173 (cm)
  • Max Equipment Depth
    29 (in) 73.66 (cm)
  • Unit Weight
    725 (lbs) 329 (kg)
  • Controls
    Automated Cooling/HVAC Control
  • Fire Suppression/Risk Management
    Integrated, Inert Gas Based
  • Cabinet Power Distribution
    Optional
  • Power Management
    Optional based on location
  • Cooling System
    Dx Air Conditioning
  • Water Temp Operating Range
    NA
  • Flow Rate
    NA
  • Air Flow
    350-800 CFM
    (594-1,360 m3/h)
  • Inter-Cabinet Cable Mgmt.
    Optional
  • Security Options
    Locks/Biometrics/2FA
ruggedized rack enclosures
  • Density Capability
    5.8-11kW
  • Rack Units
    42U
  • Measurements (HxWxD)
    95 x 30.5 x 75 (in)
    242 x 78 x 191 (cm)
  • Max Equipment Depth
    29 (in) 73.66 (cm)
  • Unit Weight
    1,100(lbs) 499(kg)
  • Controls
    Automated Cooling/HVAC Control
  • Fire Suppression/Risk Management
    Integrated, Inert Gas Based
  • Cabinet Power Distribution
    Optional
  • Power Management
    Optional based on location
  • Cooling System
    Dx Air Conditioning
  • Water Temp Operating Range
    NA
  • Flow Rate
    NA
  • Air Flow
    675 CFM
    (1,150 m3/h)
  • Inter-Cabinet Cable Mgmt.
    Optional
  • Security Options
    Locks/Biometrics/2FA

DDC R-SERIES CABINET USE CASES

  • AI ANYWHERE
  • Turnkey Data Center
  • Rapid Deployment Solution
  • Test Lab Environment
  • Instant Data Center
  • Edge Data Center
  • Urgent HPC
  • Trade Show Solution
  • AR/VR/Entertainment Solution
  • Inhospitable Environments

Get In Touch With Us

Complete the form or call our sales department at (858) 633-4386.